Chemical Storage Building
| Agency | Department of Defense Department of the Army |
| Contracting office | W6qm Micc-ft Drum |
| Place of performance | See the notice |
| Type of notice | Open for bids |
| Set-aside | Small Business Set Aside - Total |
| Response deadline | Aug 7, 2026 |
| Posted | Jul 29, 2026 |
| Solicitation number | W911S226U3863 |
| NAICS code | 238290, Other Building Equipment Contractors |
Summary from the notice
The chemical storage building must meet several specifications for construction, safety, and utility. The required minimum dimensions are 42 feet in length, 8 feet in width, and 8 feet 3 inches in height. Access shall be provided by a 60-inch by 80-inch set of double doors, with at least one 36-inch active leaf, centered on one of the 42-foot walls and secured with a padlock-compatible handle. For spill containment, the building must include a sump with a minimum capacity of 1200 gallons.The structure must feature a robust fire-rated design, with walls tested by Intertek for a minimum 4-hour rating and a roof tested for a minimum 3-hour rating. Electrical specifications include a 12-space, 100-amp NEMA 3R main breaker panel (120V/240V), two Class 1, Division 2 explosion-proof LED light fixtures with a switch for the interior, and a dust/vapor-resistant exterior light with a photocell installed outside the hazard zone. Ventilation will be handled by an explosion-proof exhaust system rated for 335 CFM or higher, suitable for petroleum-based storage and compliant with all NFPA/UFC codes, complete with an indicator light and an emergency shut-off switch.For safety and functionality, the building shall be equipped with a grounding kit including an 8-foot ground rod, 10 feet of cable, and a clamp. The interior will be furnished with three-tier, 5-foot-long shelves that are 14 inches deep with a 2-inch lip. A non-perforated, skid-resistant steel ramp, measuring at least 52 inches wi…
Other open NAICS 238290 notices
| Deadline | Notice | Set-aside |
|---|---|---|
| Oct 23 3 days left |
Multi-Zone Elevator Maintenance and Repair Services
Public Buildings Service, Kansas City, MO Sources sought |
Open to all |
| Oct 26 6 days left |
Elevator Equipment and Systems Recurring Preventative Maintenance and Non-Wear-and-Tear Repairs
Department of the Navy |
Small business |
| Oct 29 9 days left |
561A4-25-500 Elevator Upgrade & Modernization Repairs at VA NJ HCS Lyons Buildings 6 & 53
Department of Veterans Affairs, Lyons, NJ |
SDVOSB |
| Oct 29 9 days left |
Modernize Damen (Bldg. 1) Elevators Construction 537-24-101
Department of Veterans Affairs, Chicago, IL |
SDVOSB |
| Oct 30 10 days left |
Replace Chairlift-FCI Loretto
Federal Prison System / Bureau of Prisons, Loretto, PA |
Small business |
| Nov 5 16 days left |
Dike B Generator Installation, Mansfield Hollow Dam, Mansfield Center, CT
Department of the Army, Mansfield Center, CT Pre-solicitation |
Small business |
Details copied from the public SAM.gov notice. BidFox is not connected to SAM.gov or the U.S. Government, so check the official notice before you bid.