155mm Video Bore Inspection System (VBIS) scanner and 155mm LBIS, LVDT, VBIS Delivery Unit
| Agency | Department of Defense Department of the Army |
| Contracting office | W6qm Micc-ft Drum |
| Place of performance | See the notice |
| Type of notice | Open for bids |
| Set-aside | None, open to all businesses |
| Response deadline | Jan 27, 2026 |
| Posted | Jan 20, 2026 |
| Solicitation number | W911S226U2470 |
| NAICS code | 334513, Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables |
Summary from the notice
Camera Unit? High-resolution Side-facing Camera. This camera shall have a resolution of 12MPixels or better, focused on the bore surface with a surface field of view of approximately 30 degrees, with adjustable resolution for still images and video. The camera should support 1080p video at 11 frames per second, and full resolution at 6 frames per second. The radial focus range should be at least 3.05 to 3.25 inches (77.5 - 82.5mm)? Down-bore Camera. This camera shall have a resolution of 5MPixels or better, imaging the bore of the tube. The camera should support 1080p video at 52 frames per second and full resolution at 22 frames per second, with a fixed focus and field of view of at least 120 degrees, depending on the lens selected. The lens shall be selected with customer input.? Scanner body. The scanners shall contain a 360? rotating module that contains both cameras. Continuous rotation is not required. ? Centering. The scanner body shall have centering feet for a 155mm bore, to ensure adequate centering of the camera to the side camera in focus throughout the rotation.? Lighting. The scanner body shall include LED lighting that provides visibility of the sidewall for both cameras. The lighting control shall be user-controlled and also turn on automatically during photos or videos.? Camera Connectivity. The Camera Unit shall allow the user to switch the real-time view between the two cameras. ? Temperature. The operating temperature range should be from 0 to 50?C? Cable.…
Other open NAICS 334513 notices
| Deadline | Notice | Set-aside |
|---|---|---|
| Oct 22 Closes today |
Transmitter, Pressur
Defense Logistics Agency |
Small business |
| Oct 22 Closes today |
Transmitter, Pressure
Defense Logistics Agency |
Small business |
| Oct 23 1 day left |
Switch, Liquid Level
Defense Logistics Agency |
HUBZone |
| Oct 23 1 day left |
Switch, Pressure
Defense Logistics Agency |
Open to all |
| Oct 22 1 day left |
Upgrade Building Automation System
Department of Veterans Affairs Sources sought |
Open to all |
| Oct 23 1 day left |
Transducer, Pressure, FL
Defense Logistics Agency |
Small business |
Details copied from the public SAM.gov notice. BidFox is not connected to SAM.gov or the U.S. Government, so check the official notice before you bid.