Blasting Cabinets
| Agency | DEPT OF DEFENSE DEPT OF THE ARMY |
| Contracting office | W6QK ACC-RSA |
| Where | CORPUS CHRISTI, TX |
| Type of notice | Open for bids |
| Set-aside | None, open to all businesses |
| Response deadline | Mar 25, 2019 |
| Posted | Mar 14, 2019 |
| Solicitation number | w58rgz19r0256 |
| NAICS code | 333999 |
Summary from the notice
Question 8: Can we be slightly larger than the SOW says? Answer: 1. For the small blast cabinets the SOW already has the para listed below but if the work chamber exceeds the 48'' W x 48'' D x 40'' H by a few inches it will still need to fit in the area and get through the entrance door as stated in the SOW: 3.3.1.1 The work chamber shall have a minimum inside dimensions of 42" W x 42" D x 32" H. Due to space restrictions, the work chamber shall not exceed 48'' W x 48'' D x 40'' H. 3.3.1.2 Total system footprint (including cabinet, reclaimer, and dust collector) for each individual unit shall not exceed 11'9" W x 12'5''D x 10' H. This area shall include a 3ft safety distance for all electrical panels, maintenance locations, waste removal path, and access points. The proposed operation orientation to adhere to these dimensions shall be included with the equipment drawings submitted for para 3.1.1.14 as part of the bid proposal. 2. For the medium blast cabinets the SOW already has the para listed below but if the work chamber exceeds the 60'' W x 48'' D x 40''H by a few inches it will still need to fit in the area and get through the entrance door as stated in the SOW: 3.2.1.1 The work chamber shall have a minimum inside dimensions of 50" W x 44" D x 32" H. Due to space restrictions, the work chamber shall not exceed 60'' W x 48'' D x 40'' H accept for by a few inches but the cabinet will still need to fit in the area and get through the entrance door. 3.2.1.2 The doors on each…
Details copied from the public SAM.gov notice. BidFox is not connected to SAM.gov or the U.S. Government, so check the official notice before you bid.