BidFox

Boiler 3 Oxygen Analyzer and Steam Flow Meter

3 days left Open for bids SDVOSB set-aside NAICS 238220

Don't miss the next one. BidFox emails you every morning the new construction notices in Georgia that fit your business. 7 days free, cancel online anytime.

AgencyDepartment of Veterans Affairs
Contracting office247-network Contract Office 7 (36c247)
Place of performanceDublin, GA
Type of noticeOpen for bids
Set-asideService-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Response deadlineOct 26, 2026
PostedOct 22, 2026
Solicitation number36C24727Q0050
NAICS code238220, Plumbing, Heating, and Air-Conditioning Contractors

Read the official notice on SAM.gov

Summary from the notice

Questions and Answers 36C24727Q0050 Boiler #3 Oxygen Analyzer and Steam Flow Meter RFI Responses Where should the output signals from the new steam flow meter and O2 analyzer terminate? For example, the existing building automation system (BAS), the existing Boiler 3 burner/boiler controls, or a local display only. Burner 3 boiler/burner controls where applicable and local display. Does the government require active O2 trim control to the burner fuel/air ratio, or monitoring and display of the O2 only? Oxygen analyzer must send signals/information to combustion controls to control trim. What is the material of construction for the stack? Is it single or double wall? Stack is double walled. Inside material is steel; outside material is galvanized steel. Stack is 36 D Selkirk Metalbestos Model P.S. Current operating pressure and temperature of the system for boiler #3? Design pressure is 200 psi. Typical operating pressure is 82 psi. Typical operating temperature is about 330 degrees Fahrenheit. What are the available outputs on the physical steam flow meter (e.g., 4-20 mA, Modbus RTU, BACnet MS/TP)? 4-20 mA analog. Is the flow meter wired directly into an analog terminal block on the CB Hawk, or is it wired directly to the facility s Building Automation System (BMS)? Steam flow meter is wired into local CB Hawk analog terminal block. Please provide nameplates for the existing oxygen analyzer and steam flow meter. Oxygen analyzer nameplate: Steam flow meter nameplate:

Other open NAICS 238220 notices

DeadlineNoticeSet-aside
Oct 23
Closes today
FMC Devens - Replace Boiler Burners (3) Project 26Z2BF8
Federal Prison System / Bureau of Prisons, Ayer, MA
Small business
Oct 23
Closes today
Reverse Osmosis System Modifications
Department of Veterans Affairs, Minneapolis, MN
Open to all
Oct 23
Closes today
HVAC Repair JV Resource_jordan Valley
Bureau of Land Management
Small business
Oct 23
Closes today
Rosebud Agency HVAC Upgrade
Bureau of Indian Affairs
Open to all
Oct 23
Closes today
El Paso Lift Station Piping Repair
Department of Veterans Affairs
SDVOSB
Oct 26
3 days left
Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement
Department of the Air Force, JBSA Ft Sam Houston, TX Sources sought
Open to all

Details copied from the public SAM.gov notice. BidFox is not connected to SAM.gov or the U.S. Government, so check the official notice before you bid.

7 days freeCancel online anytime Start free trial